AMBER Archive (2008)Subject: Re: AMBER: gasteiger is not working with ambertools 1.0
From: David A. Case (case_at_scripps.edu)
Date: Mon Jun 02 2008 - 19:12:55 CDT
On Mon, May 19, 2008, Alan wrote:
>
> antechamber -i dmp.pdb -fi pdb -o dmp_gas_sybyl.mol2 -fo mol2 -c gas
> -s 2 -df 0 -at sybyl
>
> Error message: The net charge of the molecule (-9999) does not equal
> to the total charge (0.00 ) based on Gasteiger atom type, exit
>
> is simply not working anymore. It was working pretty fine with antechamber
> 1.27.
>
antechamber now seems(?) to require the user to specify the net charge (via
the -nc option) when computing gasteiger charges. It doesn't (any longer?)
default to zero. (This is based on a quick read of the sources.)
So, try adding '-nc 0' to your command line and see if that helps.
...good luck...dac
-----------------------------------------------------------------------