AMBER Archive (2005)Subject: AMBER: Improper Torsional Parameters
From: Ilyas Yildirim (yildirim_at_pas.rochester.edu)
Dear All,
Does anyone of u know how the improper torsional parameters enter into the
CK-CB-N*-CT 1.0 180. 2.
How are these parameters used in the energy calculation?
In the parm99 file (for example), sometimes the wild-card is used, as it
X -X -C -O 10.5 180. 2. JCC,7,(1986),230
The first example is the specific case while the second one is the generic
As it is described in the manual, for the dihedrals, if PK=3.0 and
X -CT-CT-X 9 3.0/2 Phase PN
If we want to use this dihedral definition for a specific case, then the
HC-CT-CT-HC 1 3.0/2/9 Phase PN
For the dihedral case, this is the connection. I could not understand the
X -X -C -O 10.5 180. 2. JCC,7,(1986),230
Can I use the following parameter in my frcmod file (in case I need it)?
NC-CM-C -O 10.5 180. 2.
Or do I have to change something from the original parameter when I skip
Best,
-- Ilyas Yildirim --------------------------------------------------------------- - Department of Chemisty - - - University of Rochester - - - Hutchison Hall, # B10 - - - Rochester, NY 14627-0216 - Ph.:(585) 275 67 66 (Office) - - http://www.pas.rochester.edu/~yildirim/ - ---------------------------------------------------------------
| |||||||||||||||||||||||||||||||||
|