AMBER Archive (2005)Subject: RE: AMBER: Antechamber RESP failed for large organic molecule
From: Junmei Wang (jwang_at_encysive.com)
Date: Tue May 31 2005 - 09:37:35 CDT
The respgen program automatically expends the sizes of arrays and the
result is OK, just ignore the warning message.
All the best
Junmei
==================================================
Dr. Junmei Wang
Chemistry & Biophysics
Encysive Pharmaceuticals Inc.
7000 Fannin, Houston TX 77030
Tel: 713-578-6649
Email: jwang_at_encysive.com
http://amber.scripps.edu/antechamber/antechamber.html
==================================================
Dear AMBER developers and users:
I succeeded in creating user-defined residule template .prepin file by
antechamber with resp charging method for a small organic molecule(10
atoms). But when I fed the Gaussian output file(.log) for a large
molecule(132 atoms) to antechamber with the command
"antechamber -i MER.log -fi gout -o MER.prepin -fo prepi -c resp -s 2",
the resp charge fitting process failed with the following report: the
number of the path atoms exceeds(MAXPATHATOMNUM=10000) for
atom[0],extend the size and reallocate the memory the number of the path
atoms exceeds(MAXPATHATOMNUM=10000) for atom[1],extend the size and
reallocate the memory .. .. lib-4001 : UNRECOVERABLE library error .. ..
Can not open charge file QOUT, exit
But after checking MER.log file by hand, everything looks fine. Mulliken
charges and ESP charges have been assigned to each atom.
Does this mean I need to modify parameter MAXPATHATOMNUM in some file?
Best regards,
Sincerely,
Jun WANG
Department of Chemistry
University of Nebraska-Lincoln
536 Hamilton Hall
Lincoln, NE 68588-0304
U.S.A.
E-mail:junwang_at_unlserve.unl.edu
junwang_at_bigred.unl.edu
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu