| AMBER Archive (2005)Subject: Re: AMBER: "The system has extended beyond" error
From: Ilyas Yildirim (yildirim_at_pas.rochester.edu)Date: Thu Mar 31 2005 - 06:26:21 CST
 
 
 
 
Dear Mr. Case,
 Thanks for the suggestion. After setting nscm = 500 (before it was 1000)
the system did not give any error for 200 ps simulation.
 
 Best,
 On Wed, 30 Mar 2005, David A. Case wrote:
 > On Tue, Mar 29, 2005, Ilyas Yildirim wrote:
> >
 > > As far as I understand, the above error is saying that the molecule is out
 > > of the virtual box sander has created.
 >
 > You should visually look at your trajectory to see what is happening.  The
 > most likely fix is probably to set the nscm parameter to prevent center of
 > mass translation.  But it is also possible that you molecule is flying apart
 > into to pieces.
 >
 > ...dac
 >
 > -----------------------------------------------------------------------
 > The AMBER Mail Reflector
 > To post, send mail to amber_at_scripps.edu
 > To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 >
 >
 
 
-- 
  Ilyas Yildirim
  ---------------------------------------------------------------
  - Department of Chemisty       -                              -
  - University of Rochester      -                              -
  - Hutchison Hall, # B10        -                              -
  - Rochester, NY 14627-0216     - Ph.:(585) 275 67 66 (Office) -
  - http://www.pas.rochester.edu/~yildirim/                     -
  ---------------------------------------------------------------
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 
 
 |