AMBER Archive (2005)Subject: Re: AMBER: OH- dynamics
From: Carlos Simmerling (carlos_at_ilion.bio.sunysb.edu)
Date: Wed Mar 30 2005 - 13:14:07 CST
I don't think you'll be able to use nscm in this case....
Eric Hu wrote:
>Hi, I want to do a OH- dynamics is vaccum and water. I got the
>following error in vaccum:
>
>%CENMAS-F-INERTIA_TENSOR, determinant is zero ... stop
>
>I suspect that this is caused by the linearity of OH-. How do I get
>around this error? Thanks.
>
>
>Eric
>
> title here
>&cntrl
> ntr=0,
> nstlim =20000, nscm=2000, ntave=5000,
> ntx=1, irest=0, ntb=0, cut=99, ntpr=100, tempi=300.0, ig=974651,
> ntp=0, taup=1.0,
> dt=0.001, nrespa=1,
> ntt=1, temp0 = 300., tautp=2.0,
> ntc=2, ntf=2, tol=0.000001,
> ntwr = 10000, ntwx=0,
> icfe=1, clambda=0.04691,
>
>/
>-----------------------------------------------------------------------
>The AMBER Mail Reflector
>To post, send mail to amber_at_scripps.edu
>To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
>
>
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu