AMBER Archive (2005)Subject: AMBER: "ERROR TERMINATION DUE TO SHAKE OR TORCON" in Gibbs
From: tanc_at_uci.edu 
Date: Tue Mar 22 2005 - 23:11:41 CST
 
 
 
 
Hi, All,
 
    I am using Gibbs Dynamically Modified Windows method to perturb a VAL
 
analog ( without any partial charge ) into nothing in water. INTR = 46 is
 
used to make the molecule rigid, and NTR = 1 with factor 50.  But when
 
lambda moved to 0.15 (from 1), Gibbs terminated with the error message:
 
 ERROR TERMINATION DUE TO SHAKE OR TORCON
 
I tried to restart it but failed with same message.  So, could anybody
 
tell me how I can restart my job?
 
(By the way,  it can be restarted with INTR=0, but I need INTR=1.)
 
 Following is the input and part of output file:
 
 # Thermodynamic integration with dynamic windows.
 
 &cntrl
 
   irest  = 1,  ntx = 7, init = 4,
 
   ntt    = 1,
 
   ntb    = 2,  ntp = 1, temp0 = 300.0,
 
   ntf    = 2,  ntc = 2, tol = 0.0001, tolr2 = 0.0001
 
   scee   = 1.2,
 
   nstlim = -1,  dt = 0.001,
 
   ielper = -1, idsx0 = 200,
 
   idifrg = 1,  intprt = 0,
 
   almda  = 1, isldyn = -2,  amxmov = 0.02, amxrst = 0.1, dlmax = 0.025,
 
   nstmeq = 40000, nstmul = 40000,
 
   ntpr   = 40000, isande = 1, ntwx = -1,
 
   cut    = 15., ntr = 1, intr = 46
 
 &end
 
Hold the nucleic acid fixed
 
50.0
 
RES 1 1
 
END
 
END
 
00001 00002 00000 00000 00000 00000 00002 001.00000 000.00000
 
000.00000 999.00000 000.00000 999.00000 00000 00000
 
00001 00011 00000 00000 00000 00000 00002 001.00000 000.00000
 
000.00000 999.00000 000.00000 999.00000 00000 00000
 
00003 00004 00000 00000 00000 00000 00002 001.00000 000.00000
 
000.00000 999.00000 000.00000 999.00000 00000 00000
 
.............................
 
  Current Lambda =   0.143248
 
 Last F.E. update: Lambda =   0.150083  Step =          0  Method = T.I.
 
 Accumulated "forward" quantities (Nonbond change)
 
    Lambda   =  0.150083    F_energy  =    2.19930
 
    Enthalpy = -255.09230   T*Entropy = -257.29160
 
    (Note: values are unchanged from last report)
 
 ------------------------------------------------------------------------------
 
      Routine TORCON (internal constraints) failed.
 
     Required change is too large.
 
     NITER =     1 Bond atom numbers are:     7   10
 
 Current Lambda =   0.143248
 
 Last F.E. update: Lambda =   0.150083  Step =          0  Method = T.I.
 
 Accumulated "forward" quantities (Nonbond change)
 
    Lambda   =  0.150083    F_energy  =    2.19930
 
    Enthalpy = -255.09230   T*Entropy = -257.29160
 
    ELEC =      0.000    NONB =      2.199    14NB =      0.000
 
    14EL =      0.000    BADH =      0.000
 
 Quantities used in integration:
 
    <dV/d_lam> =        2.4782850      <V(lam-dep.)> =           60.637060
 
    <V(lam-indep.)> =  -6356.2590      <V(lam-dep)*dV/d_lam> =   186.64760
 
    <V(lam-indep)*dV/d_lam> =  -15785.460
 
 ------------------------------------------------------------------------------
 
 NO DYNAMICALLY MODIFIED WINDOWS COLLECTED SINCE LAST REPORT
 
      Routine        Sec       %
 
     ----------------------------
 
|     Pairlist        1.45    0.91
 
|     Nonbond       154.12   96.48
 
|     Bond            0.02    0.01
 
|     Angle           0.04    0.03
 
|     Dihedral        0.07    0.04
 
|     PMF             0.00    0.00
 
|     Constraint      2.86    1.79
 
|     Other           1.18    0.74
 
|     Nonsetup      159.71   99.98
 
      ----------------------------
 
|     Total         159.74    0.04 Hours
 
 |    Setup wallclock_t             0 seconds
 
|    Nonsetup wallclock_t        161 seconds
 
           ***** ERROR TERMINATION DUE TO SHAKE OR TORCON *****
 
 -----------------------------------------------------------------------
 
The AMBER Mail Reflector
 
To post, send mail to amber_at_scripps.edu
 