AMBER Archive (2005)

Subject: Re: Re :AMBER: Holes in water

From: Carlos Simmerling (carlos_at_ilion.bio.sunysb.edu)
Date: Sat Mar 12 2005 - 12:32:06 CST


is it possible that you are restraining the water back to the initial
positions? that would re-form the holes. try using the restraints
during the pressure equilibration too.
please let us know what your coordinates for -ref are and
what your restraintmask is. also the first energy evaluation
with the restraint energy. check the sander output when it
processes the restraintmask - is it correct?

don't mix the terms constraint and restraint, they mean
very different things. you are using restraints, not constraints.

===================================================================
Carlos L. Simmerling, Ph.D.
Associate Professor Phone: (631) 632-1336
Center for Structural Biology Fax: (631) 632-1555
Stony Brook University Web: http://comp.chem.sunysb.edu/carlos
Stony Brook, NY 11794-5115 E-mail: carlos.simmerling_at_stonybrook.edu
===================================================================

Lukasz Bielecki wrote:

> Thanks for the hints but actually I AM using the constant pressure MD
> and this is where the holes/voids do form. In fact, after the belly
> stage of the NPT dynamics, the system is well equilibrated, with the
> volume shrinked exactly as in the manual - and then at the next stage
> - where I am using positional constraints (NTR=1; RESTRAINT_WT and
> RESTRAINTMASK parameters used - it is AMBER 8), the system again
> expands and holes form. It is constant pressure, as well here.
> Interestingly, when I am deleting the constraints from the input file
> (and set NTR to 0), the system does not expand and holes don't seem to
> emerge. So maybe there is some problem with the NTR=1 option? But I
> actually need constraints in my experiment, the unconstrained run was
> just a test.
>
> Thank you for your help,
>
> Lukasz
>
>
> On Fri, 11 Mar 2005, Pascal Auffinger wrote:
>
>> Well its quite easy. During the setting up of the system there is just
>
> no
>
>> way to get an optimal compaction of the solvent. Then during the MD the
>> system compacts itself, especially around the solute and then you get
>
> see
>
>> the formation of holes since the box size (pressure) cannot adjust.
>>
>> Pascal
>>
>>> Dear Amber experts,
>>>
>>> When I perform constant pressure MD of a nucleic acid in a TIP3P
>>
> solvation
>
>>> box (PME), I get increasing holes or voids in the solvent part of the
>>> system. What can be the reason for this? The system seems to be well
>>> energy minimized, then smoothly heated to 300K, and at those initial
>>> stages no holes appear, only during the later production run.
>>>
>>> Many thanks for your help,
>>>
>>> Dr. Lukasz Bielecki
>>
>
>
>
> On Fri, 11 Mar 2005, Bill Ross wrote:
>
>> See the FAQ on equilibration - constant pressure is needed to
>> let the box shrink to the correct density.
>>
>> Bill
>> -----------------------------------------------------------------------
>> The AMBER Mail Reflector
>> To post, send mail to amber_at_scripps.edu
>> To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
>>
>
> Lukasz Bielecki
>
> 'Health is merely the slowest possible rate at which one can die'
>
> -----------------------------------------------------------------------
> The AMBER Mail Reflector
> To post, send mail to amber_at_scripps.edu
> To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu