AMBER Archive (2002)Subject: Partial charge generation RESP/antechamber
From: James W. Caldwell (caldwell_at_heimdal.compchem.ucsf.edu)
Please note the following regarding Gaussian98 and
The FINAL set of molecular properties in a G98 output
If you run a single point, that is the only one.
The reason I'm bringing this up is that the script
On the other hand, Antechamber is programed to look for
To clarify the Antechamber G98 input in the sample run:
#HF/6-31G* SCF=tight Test Pop=MK iop(6/33=2) iop(6/42=6) opt
HF/6-31G* calculation type and basis set
SCF=tight normally G98 does optimizations at a
Test extra output
Pop=MK Do a Merz-Kollman ESP fit to get partial charges
iop(6/33=2) Output the ESP data to the standard output file
iop(6/42=6) calculate 6 points per unit area for the ESP, the
opt do a geometry vs. energy optimization of the input
--
| |||||||||||||||||||||||||||||||||
|