AMBER Archive (2002)Subject: md equilibration in chloroform
From: Sophia Kondratova (x357l_at_unb.ca) 
Date: Mon Jul 08 2002 - 08:38:27 CDT
 
 
 
 
I am having difficulties equilibrating a ligand/receptor complex in a 
 
chloroform box. I need to equilibrate the system to 300K in an NPT ensemble 
 
with SHAKE. What value of COMP(compressibility of the system) should I be 
 
using? ( 700 chcl3 in the box, 50.7410000  49.2030000  50.8920000 dimensions)
 
If anyone has done chloroform simulations, maybe they could tell me what 
 
parameters are used to correctly equilibrate a chloroform box. Should I 
 
equilibrate first using an NVT ensemble? The error message that I get when I 
 
try to equilibrate:
 
 Coordinate resetting (SHAKE) cannot be accomplished,
 
     deviation is too large
 
     NITER, NIT, LL, I and J are :    0    3 2956 3651 3649
 
      Note: This is usually a symptom of some deeper
 
     problem with the energetics of the system.
 
 Any help would be greatly appreciated.
 
 Sophia Kondratova
 
Chemistry Department
 
University of New Brunswick
 
Canada
 
 
  
 |