On Tue, Mar 09, 2004, Byungchan Kim wrote:
> >
> > As far as I know, ewald calculation for electrostatics should be performed
> > on neutral system. But I found several articles in which I think ewald was
> > performed on charged system. I mean total net charge of the molecular
> > system is not zero. So is it correct to use ewald for charged system?

Ewald (or PME) on charged systems implicitly include a uniform "neutralizing
plasma" that makes the whole system net neutral.

See http://amber.scripps.edu/Questions/mail/103.html.