AMBER Archive (2009)

Subject: Re: [AMBER] About APBS radiopt

From: Robert Konecny (rok_at_ucsd.edu)
Date: Mon Dec 28 2009 - 09:43:18 CST


Hi,

if you are referring to the radiopt keyword in sander.APBS then if you set
it to 0 the PB solver will use both charge and radius information from the
prmtop file. Unless you wish to modify the charge and/or radius values you
don't need any additional files.

Good luck,

Robert

On Mon, Dec 28, 2009 at 07:12:07PM +0900, Youn Kyeung Lee wrote:
> Hi,
>
> I have a question about radiopt in APBS.
> In manual, it says, if I set radiopt as 0, the radii from prmtop files are
> used for PB calculation.
> I wonder that APBS also reads charges from prmtop file.
> Do I need another file for setting the same charges as those in prmtop file?
>
> Thank U
> _______________________________________________
> AMBER mailing list
> AMBER_at_ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber

_______________________________________________
AMBER mailing list
AMBER_at_ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber