AMBER Archive (2009)Subject: Re: [AMBER] ptraj utility
From: case (case_at_biomaps.rutgers.edu) 
Date: Tue Dec 01 2009 - 06:56:52 CST
 
 
 
 
On Tue, Dec 01, 2009, Neha Bharat Gajaria wrote:
 
> 
 
> I m trying to extract the distance between two Calpha atoms from amber
 
> trajectories using ptraj. The average distance should be 10.05 Ang. After
 
> 50ns or so, the distances reported in the output are very unusual.
 
> 
 
> The output looks like
 
> 9.45
 
> 9.85
 
> .
 
> .
 
> .
 
> 40.23
 
> 33.12
 
> 
 
> .
 
> .
 
> .
 
> 8.10
 
> 8.93
 
> 
 
> Are some of the trajectories corrupted or something is going wrong with the
 
> box? thanking you for your response
 
 If the two CA atoms are in the same polypeptide chain, then it should not be
 
an artifact.  Visualize the trajectory and see what happens at the time steps
 
when the distance is large.  If the two CA atoms are in different molecules,
 
it could be imaging problem...use the image command in ptraj to bring
 
everything back to the main unit cell before issuing the distance command.
 
 ...dac
 
 _______________________________________________
 
AMBER mailing list
 
AMBER_at_ambermd.org
 
http://lists.ambermd.org/mailman/listinfo/amber
 
 
  
 |