AMBER Archive (2009)Subject: Re: [AMBER] slope
From: Jio M (jiomm_at_yahoo.com)
Dear Sir,
I am using following input file
&cntrl
nstlim=1050000,
ntt=3, gamma_ln=5,
scee=1.2,
ntpr=500, pencut=0.1,
nmropt=1,
vlimit=10,
ntb=0,dt = 0.0005,cut=999,ntwx=500
/
&wt type='TEMP0', istep1=0,istep2=140000,
value1=300.0, value2=2000.0
/
&wt type='TEMP0', istep1=140001,istep2=200000,
value1=2000.0, value2=2000.0
/
&wt type='TEMP0', istep1=200001,istep2=340000,
value1=2000.0, value2=1000.0
/
&wt type='TEMP0', istep1=340001,istep2=480000,
value1=1000.0, value2=2000.0
/
&wt type='TEMP0', istep1=480001,istep2=620000,
value1=2000.0, value2=1000.0
/
&wt type='TEMP0', istep1=620001,istep2=760000,
value1=1000.0, value2=2000.0
/
&wt type='TEMP0', istep1=760001,istep2=900000,
value1=2000.0, value2=1000.0
/
&wt type='TEMP0', istep1=900001,istep2=1050000,
value1=1000.0, value2=300.0
/
&wt type='END'
/
--- On Sun, 11/15/09, Carlos Simmerling <carlos.simmerling_at_gmail.com> wrote:
From: Carlos Simmerling <carlos.simmerling_at_gmail.com>
for (1) it all depends on how you set the thermostat temp0, which
On 11/15/09, Jio M <jiomm_at_yahoo.com> wrote:
-- =================================================================== Carlos L. Simmerling, Ph.D. Professor, Department of Chemistry CMM Bldg, Room G80 Phone: (631) 632-1336 Fax: 632-1555 Stony Brook University E-mail: carlos.simmerling_at_gmail.com Stony Brook, NY 11794-5115 Web: http://www.simmerlinglab.org ===================================================================
| |||||||||||||||||||||||||||||||||
|