Hi Syed,

> I am simulating the aminoacid in water of 15 Angstrom layer using QM/MM
> implemented in amber10 using AM1 theory, but i am getting the following
> error, QM-Cutoff is larger than a box and you require a larger box.

This is saying that the size of the QM region + the cutoff would extend
beyond the edges of the box. The net result of this is that the system would
see its own images in the direct space sum which is not permitted.
Essentially this means that either your qmcut is too large (8 to 10
angstroms is probably good) and or your water box (QM+MM) is too small.

You should note though that if you are including water in the QM region it
will diffuse during the simulation into the MM water and this will
ultimately result in the calculation failing with the above error since the
effective size of your QM region will have grown as the water diffuses. I
have been developing approaches to deal with the issue of including mobile
waters in the QM region but this will not be ready until the next version of
AMBER is released.

Good luck,
Ross

/\
\/
|\oss Walker

| Assistant Research Professor |
| San Diego Supercomputer Center |
| Tel: +1 858 822 0854 | EMail:- ross_at_rosswalker.co.uk |
| http://www.rosswalker.co.uk | PGP Key available on request |

Note: Electronic Mail is not secure, has no guarantee of delivery, may not
be read every day, and should not be used for urgent or sensitive issues.

_______________________________________________
AMBER mailing list
AMBER_at_ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber