AMBER Archive (2008)Subject: AMBER: ptraj closest command
From: steinbrt_at_rci.rutgers.edu
Date: Mon Nov 17 2008 - 10:14:11 CST
Hi Amber users,
Im having trouble using ptraj's closest command to select a few water
molecules closest to a solute. Heres my input:
--------------------------------------------------------------
trajin ph0_wat_pro.crd_img
solvent byres :WAT
closest 3 @1
trajout ph0_wat_pro.crd_img_3w pdb
--------------------------------------------------------------
the coordinate file read is centered on molecule 1 and imaged.
ptraj runs fine and gives output that looks unsuspicious:
--------------------------------------------------------------
PTRAJ: Processing input from "STDIN" ...
PTRAJ: trajin ph0_wat_pro.crd_img
Checking coordinates: ph0_wat_pro.crd_img
PTRAJ: solvent byres :WAT
Mask [:WAT] represents 2259 atoms
Searching for solvent by mask :2-754
PTRAJ: closest 3 @1
Mask [@1] represents 1 atoms
PTRAJ: trajout ph0_wat_pro.crd_img_3w pdb
PTRAJ: Successfully read the input file.
Coordinate processing will occur on 1000 frames.
Summary of I/O and actions follows:
INPUT COORDINATE FILES
File (ph0_wat_pro.crd_img) is an AMBER trajectory (with box info) with
1000 sets
OUTPUT COORDINATE FILE
File (ph0_wat_pro.crd_img_3w) is a PDB file
ACTIONS
1> CLOSESTWATERS: saving the 3 closest solvent molecules around atoms
:1_at_P1
The current solvent mask is :2-754
Processing AMBER trajectory file ph0_wat_pro.crd_img
....
-----------------------------------------------------------
but the pdb files produced do not contain the closest waters:
e.g.:
REMARK 1 PDB file generated by ptraj (set 1000)
ATOM 1 P1 po4 1 0.008 0.012 0.000 0.00 0.00
[...]
TER 0 0
ATOM 12 O WAT 4 12.041 -7.377 -10.470 0.00 0.00
ATOM 13 H1 WAT 4 12.964 -7.450 -10.712 0.00 0.00
ATOM 14 H2 WAT 4 12.043 -6.842 -9.677 0.00 0.00
Visual inspection shows that there are water molecules much closer to the
solute than the ones ptraj actually picks (the solute is small and the
closest waters are no more than 3-4A away).
Is there anything obvious I overlooked? Any suggestions what Im doing
wrong? (Using the noimage command doesnt change anything, neither does
picking the full residue :1 as mask in closest)
Kind Regards,
Thomas
Dr. Thomas Steinbrecher
BioMaps Institute
Rutgers University
610 Taylor Rd.
Piscataway, NJ 08854
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)