AMBER Archive (2008)

Subject: RE: AMBER: problem with group input and NMR restaints

From: Ross Walker (ross_at_rosswalker.co.uk)
Date: Tue Nov 04 2008 - 09:46:17 CST


Hi Priya,

I'm not sure if you can use NMR restraints with harmonic restraints, I have never tried it although I don't see why it wouldn't work. With regards to your input I think the group input has to come last. so your input should probably be:

Stage 1
 &cntrl
  imin=0, irest=0, ntx=1,
  nstlim=100000, dt=0.002,gbsa =1,surften=0.005,
  ntc=2, ntf=2,ntr=1,
  ntt=3, gamma_ln =5.0,
  tempi=0.000, temp0=300.19,
  ntpr=500, ntwx=500, ntwr = 500,
  ntb=0, igb=1,nmropt=1,
  cut=16
  /
 &wt type= 'REST', istep1 =0, istep2=0, value1=1.0, value2=1.0, /
 &wt type='END' /
  DISANG=rst
END
hold the protein fixed
10.0
ATOM 1 900
END
END

Although you may have to experiment here to be sure.

Good luck,
Ross

/\
\/