| AMBER Archive (2008)Subject: RE: AMBER: stripping water from a restart file
From: CHAMI F. (fatima.chami_at_durham.ac.uk)Date: Fri Oct 24 2008 - 04:58:58 CDT
 
 
 
 
 
 ________________________________
 From: owner-amber_at_scripps.edu on behalf of Bill Ross
Sent: Fri 24/10/2008 00:48
 To: amber_at_scripps.edu
 Subject: RE: AMBER: stripping water from a restart file
 
 > I am trying to run an SMD simulation  with  4 residues in vacuum and i =
> got the following message :
 >  Must have more residues than processors!
 >
 > and job stopped ...does it mean I cant run this simulation on this =
 > system
 
 Allocate fewer processors - one should do.
 It does run with two processors but again stopped for a different error this time. I pasted the output file here:
 NMR restraints: Bond =    0.996   Angle =     0.000   Torsion =     0.000
 ===============================================================================
 NSTEP =     9000   TIME(PS) =       9.000  TEMP(K) =   324.18  PRESS =     0.0
 Etot   =       126.7326  EKtot   =        75.3720  EPtot      =        51.3606
 BOND   =        22.7783  ANGLE   =        45.8167  DIHED      =        48.3483
 1-4 NB =        27.7251  1-4 EEL =        83.1635  VDWAALS    =        -5.5026
 EELEC  =      -171.6326  EHBOND  =         0.0000  RESTRAINT  =         0.6639
 EAMBER (non-restraint)  =        50.6967
 ------------------------------------------------------------------------------
 NMR restraints: Bond =    0.664   Angle =     0.000   Torsion =     0.000
 ===============================================================================
 Frac coord min, max:  -1.343462511348717E-004  0.834361441303091
 The system has extended beyond
 the extent of the virtual box.
 Restarting sander will recalculate
 a new virtual box with 30 Angstroms
 extra on each side, if there is a
 restart file for this configuration.
 SANDER BOMB in subroutine Routine: map_coords (ew_force.f)
 Atom out of bounds. If a restart has been written,
 restarting should resolve the error
 
 ----------------------------------------------------------------------------------------------------------------------------------
 I rerun the same job but using the restart file which was written from the previous run but yet it did not resolve it.
 I had no problem running SMD in explicit water  using restart  files extracted from MD ...but trying to run the same simulation in vacuum  seems to be not straightforward at all ...
 thanks 
 Fatima 
  
 Bill
-----------------------------------------------------------------------
 The AMBER Mail Reflector
 To post, send mail to amber_at_scripps.edu
 To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
 to majordomo_at_scripps.edu
 
 -----------------------------------------------------------------------
The AMBER Mail Reflector
 To post, send mail to amber_at_scripps.edu
 To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
 to majordomo_at_scripps.edu
 
 
 
 |