| AMBER Archive (2008)Subject: Re: AMBER: 3fe-4s cluster parameter file generation
From: moitrayee_at_mbu.iisc.ernet.inDate: Mon Sep 15 2008 - 06:46:56 CDT
 
 
 
 
I did not use antechamber but manually did it using the co-ordinate and charge
information from the Gaussian single point calculation. The prepc file is given
 below:
 
     0    0    2
 This is a remark line
molecule.res
 F3S   XYZ  0
 CHANGE     OMIT DU   BEG
 0.0000
 1  DUMM  DU    M        999.000     999.0      -999.0           .00000
 2  DUMM  DU    M        999.000    -999.0       999.0           .00000
 3  DUMM  DU    M       -999.000     999.0       999.0           .00000
 4   S1    S    M        0.402592   -1.514288   -1.117435      -0.15436
 5   S2    S    M       -1.882611    0.670231   -0.727350      -0.17413
 6   S3    S    M        0.078709   -0.205500    1.731896      -0.31438
 7   S4    S    M        1.046182    1.057400   -1.309825      -0.13664
 8  FE1   FE    M       -1.129336   -1.094156    0.156620       0.63632
 9  FE2   FE    M        1.553155   -0.302094    0.294594       0.59276
 10  FE3   FE    M       -0.205279    1.391423    0.424303       0.55042
 
 LOOP
 IMPROPER
 DONE
STOP
 And the frcmod file is as follows:
 
 remark goes here
MASS
 S  32.060                    same as ss
 FE 55.000                    ATTN, need revision
 
 BOND
 ANGLE
 DIHE
 IMPROPER
 NONBON
S           2.0000  0.2500             same as ss
 FE          1.2000  0.0500             ATTN, need revision
 This are the files that i use. Please let me know what i can do ?
 
 Sincere Regards,
Moitrayee
 
 > On Mon, Sep 15, 2008, moitrayee_at_mbu.iisc.ernet.in wrote:
>
 >> I prepared the .prepc file for the cluster...
 >
 > You don't say how you got the prepc file.  If you used antechamber, I
 > will just repeat what was said earlier: antechamber won't work for
 > transition metals.  You will have to prepare the unit by hand.
 >
 > ...dac
 >
 > -----------------------------------------------------------------------
 > The AMBER Mail Reflector
 > To post, send mail to amber_at_scripps.edu
 > To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
 >       to majordomo_at_scripps.edu
 >
 > --
 > This message has been scanned for viruses and
 > dangerous content by MailScanner, and is
 > believed to be clean.
 >
 >
 
 
-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
      to majordomo_at_scripps.edu
 
 
 |