AMBER Archive (2008)Subject: AMBER:
From: Boutheina Kerkeni (b.kerkeni_at_ucl.ac.uk)
Date: Fri Jul 04 2008 - 05:34:55 CDT
Hi AMber Users
I am running an first stage md on my system composed of a [protein(part1)
+ (part2) ] solvated and neutralized.
I want part2 to be frozen, so I did using belly. Minimizations went fine.
When I start the md job:
&cntrl
imin = 0,
irest = 0,
ntx = 1,
ntb = 1,
cut = 10,
ntr = 1,
ntc = 2, ntf = 2,
tempi = 0.0,
temp0 = 300.0,
ntt = 3,
gamma_ln = 1.0,
nstlim = 10000, dt = 0.002,
ntpr = 100, ntwx = 100, ntwr = 1000,
ibelly=1
/
Keep protein fixed with weak restraints
10.0
RES 1 796
END
END
Keep part2 fixed with belly
ATOM 1 12180 20821 80124
END
END
The calculation stops with an error :
--------------------------------------------------------------------------------
4. RESULTS
--------------------------------------------------------------------------------
---------------------------------------------------
APPROXIMATING switch and d/dx switch using CUBIC SPLINE INTERPOLATION
using 5000.0 points per unit in tabled values
TESTING RELATIVE ERROR over r ranging from 0.0 to cutoff
| CHECK switch(x): max rel err = 0.3338E-14 at 2.509300
| CHECK d/dx switch(x): max rel err = 0.8155E-11 at 2.730040
---------------------------------------------------
| Local SIZE OF NONBOND LIST = 1429347
| TOTAL SIZE OF NONBOND LIST = 24009616
NSTEP = 0 TIME(PS) = 0.000 TEMP(K) = 0.00 PRESS =
0.0
Etot = -30003.2906 EKtot = 0.0000 EPtot =
-30003.2906
BOND = 20179.4792 ANGLE = 2640.3486 DIHED =
6628.7767
1-4 NB = 2527.0010 1-4 EEL = 34717.6394 VDWAALS =
284231.0709
EELEC = -380927.6064 EHBOND = 0.0000 RESTRAINT =
0.0000
Ewald error estimate: 0.2038E-04
------------------------------------------------------------------------------
vlimit exceeded for step 1; vmax = 214.0560
Also in the log file the following message appears
-------------------------------------------
Job started at Fri Jul 4 11:25:26 BST 2008
-------------------------------------------
Coordinate resetting (SHAKE) cannot be accomplished,
deviation is too large
NITER, NIT, LL, I and J are : 0 0 4824 9785 9787
Note: This is usually a symptom of some deeper
problem with the energetics of the system.
--------------------------------------------
Job finished at Fri Jul 4 11:25:46 BST 2008
Any idea if someone has already seen such a pb?
Thanks very much for your help!
Regards
Boutheina
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
to majordomo_at_scripps.edu
|