AMBER Archive (2008)

Subject: Re: AMBER: ligand unit charge is not zero

From: mori_at_cerm.unifi.it
Date: Thu May 29 2008 - 04:17:55 CDT


You can balance the negative charge of your nucleotide by the addions or
addions2 in tleap.

amor san juan ha scritto:
> Hi,
>
> I use antechamber in tleap to generate the topology and coordinate for a ligand which is a nucleotide (Formula: C12H20N4O14P3). The warning is that the charge is equal to -3.0. Can anyone give an idea how to solve this warning?
>
> --------------------
> Checking Unit.
> WARNING: The unperturbed charge of the unit: -2.999980 is not zero.
>
> -- ignoring the warning.
>
> Building topology.
> Building atom parameters.
> Building bond parameters.
> Building angle parameters.
> Building proper torsion parameters.
> Building improper torsion parameters.
> old PREP-specified impropers:
> total 0 improper torsions applied
> 0 improper torsions in old prep form
> Building H-Bond parameters.
> Not Marking per-residue atom chain types.
> Marking per-residue atom chain types.
> (no restraints)
>
>> edit MGO
>>
> Unit Editor: > charge MGO
> Unit Editor: Total unperturbed charge: -3.0000
> Unit Editor: Total perturbed charge: -3.0000
>
>> quit
>>
> --------------------------
>
>
>
> Thanks,
> Amor A. San Juan
>
>
> Send instant messages to your online friends http://uk.messenger.yahoo.com
> -----------------------------------------------------------------------
> The AMBER Mail Reflector
> To post, send mail to amber_at_scripps.edu
> To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
> to majordomo_at_scripps.edu
>
>
> __________ Informazione NOD32 3142 (20080528) __________
>
> Questo messaggio � stato controllato dal Sistema Antivirus NOD32
> http://www.nod32.it
>
>
>
>
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)