AMBER Archive (2008)Subject: RE: AMBER: cntrl namelist error
From: Ross Walker (ross_at_rosswalker.co.uk)
Date: Sat Mar 22 2008 - 11:01:47 CDT
Hi Patrick,
> I am generating a 'Could not find cntrl namelist' error when running a
> minimization. The script that I am using is
>
> JK1WT 204aa : initial minimization whole system
> &cntrl
> imin = 1,
> maxcyc = 2500,
> ntpr = 5,
> &end
Unfortunately with email it is always difficult to see what the actual
formatting of the file was although in your case I believe it is because you
have too many spaces before the first &. There should be just a single space
before the ampesands (thus they should be in column 2.) I.e.
JK1WT 204aa : initial minimization whole system
&cntrl
imin = 1,
maxcyc = 2500,
ntpr = 5,
&end
You may also want to replace the &end with a / (again in column 2) since
some compilers prefer this. I.e.
ntpr = 5,
/
Good luck,
Ross
/\
\/
|\oss Walker
| Assistant Research Professor |
| San Diego Supercomputer Center |
| Tel: +1 858 822 0854 | EMail:- ross_at_rosswalker.co.uk |
| http://www.rosswalker.co.uk | PGP Key available on request |
Note: Electronic Mail is not secure, has no guarantee of delivery, may not
be read every day, and should not be used for urgent or sensitive issues.
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
|