AMBER Archive (2008)Subject: Re: AMBER: Temperature Range For REMD
From: Carlos Simmerling (carlos.simmerling_at_gmail.com)
Date: Thu Mar 13 2008 - 10:26:44 CDT
I don't think anyone has really determined an "ideal" temperature.
Recent work by Ron Levy shows that high temperature can make things
worse if folding is non-Arrhenius. We usually use a highest T of about
400-500K. Above that you can have stability problems and also
invert chiralities, etc, so make sure to use restraints.
On Thu, Mar 13, 2008 at 11:20 AM, tushar garud <tushar.garud07_at_gmail.com>
wrote:
> Hello sir,
> what should be the ideal temperature range for REMD of a peptide?
> And how to decide temperature for swapping (tswap)?
> peptide details: 32% helical,7% beta sheet (PDB_id:1psv)
>
> Thanks.
>
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
|