Dear Sudha,

You can use ntp=1 but with a very high relaxation time for the pressure
(taup much longer than your simulation time)

Best
vlad

Sudha Mani Karra wrote:

> Dear Amber Users,
> Can anyone help me out in explaining how we can write the
> pressure in the md.out file in a NVT simulation.
> Usually it writes the pressure = 0.0 in the case of NVT simultaion.
> below is the output line from the md.out file.
> NSTEP = 500 TIME(PS) = 2041.000 TEMP(K) = 289.50 *PRESS
> = 0.0
>
> *Thanks
> Sudha
>

-- 
----------------------------------------------------------------------------
Dr. Vlad Cojocaru

EML Research gGmbH Schloss-Wolfsbrunnenweg 33 69118 Heidelberg

Tel: ++49-6221-533266 Fax: ++49-6221-533298

e-mail:Vlad.Cojocaru[at]eml-r.villa-bosch.de

http://projects.villa-bosch.de/mcm/people/cojocaru/

---------------------------------------------------------------------------- EML Research gGmbH Amtgericht Mannheim / HRB 337446 Managing Partner: Dr. h.c. Klaus Tschira Scientific and Managing Director: Prof. Dr.-Ing. Andreas Reuter http://www.eml-r.org ----------------------------------------------------------------------------