AMBER Archive (2008)Subject: Re: AMBER: Writing pressure in md.out file in NVT simulation
From: Vlad Cojocaru (Vlad.Cojocaru_at_eml-r.villa-bosch.de)
Date: Mon Mar 03 2008 - 13:26:50 CST
Dear Sudha,
You can use ntp=1 but with a very high relaxation time for the pressure
(taup much longer than your simulation time)
Best
vlad
Sudha Mani Karra wrote:
> Dear Amber Users,
> Can anyone help me out in explaining how we can write the
> pressure in the md.out file in a NVT simulation.
> Usually it writes the pressure = 0.0 in the case of NVT simultaion.
> below is the output line from the md.out file.
> NSTEP = 500 TIME(PS) = 2041.000 TEMP(K) = 289.50 *PRESS
> = 0.0
>
> *Thanks
> Sudha
>
--
----------------------------------------------------------------------------
Dr. Vlad Cojocaru
EML Research gGmbH
Schloss-Wolfsbrunnenweg 33
69118 Heidelberg
Tel: ++49-6221-533266
Fax: ++49-6221-533298
e-mail:Vlad.Cojocaru[at]eml-r.villa-bosch.de
http://projects.villa-bosch.de/mcm/people/cojocaru/
----------------------------------------------------------------------------