It is not clear in your email on what your system is or what you want to
do. If you use icfe=1, analytically for lambda=1, dv/dl=0, which is not
printed in the .out files. If you use icfe=2, analytically for lambda=0
and lambda=1, dv/dl=0, which is not printed in the .out files.
I have systems where I am doing alchemical changes, and use icfe=2. For
clambda=0 and 1, dv/dl are always zero and are not printed out in the .out
files. For any other lambda value, dv/dl is printed out in the .out files.
On Thu, 8 Nov 2007, Cooper, Matthew wrote:
> Hi,
>
> I am experiencing difficulties with thermodynamic integration in Amber
> 9.
>
> I use the same input deck for numerous integrations. Occasionally, there
> will be no data for DV/DL, though a summary will be printed that
> contains only zeros.
>
> Rerunning the script will sometimes result in DV/DL averages being
> calculated though not always. If I run two molecules with identical
> starting positions but different charges, one may fail while the other
> will not.
>
> Does anyone have any experience with this?
>
> David wrote a while ago, in response to a similar question:
>
> <<Are you sure that the two Hamiltonians are really different? Try a
> one-step
> run with clambda=0, and with clambda=1 to make sure you are really
> getting
> different energies. (The behavior you report, not geting DV/DL at each
> step, but still getting a summary, with all values zero, is consistent
> with not having any energy difference between the two Hamiltonians.)>>
>
> I have checked - the energies are different at clambda = 0 and clambda =
> 1, at least according to the average after 1250 steps.
>
> Thanks,
>
> Matt
>
> ------------------------------------------------------------------------------
> Notice: This e-mail message, together with any attachments, contains
> information of Merck & Co., Inc. (One Merck Drive, Whitehouse Station,
> New Jersey, USA 08889), and/or its affiliates (which may be known
> outside the United States as Merck Frosst, Merck Sharp & Dohme or MSD
> and in Japan, as Banyu - direct contact information for affiliates is
> available at http://www.merck.com/contact/contacts.html) that may be
> confidential, proprietary copyrighted and/or legally privileged. It is
> intended solely for the use of the individual or entity named on this
> message. If you are not the intended recipient, and have received this
> message in error, please notify us immediately by reply e-mail and then
> delete it from your system.
>
> ------------------------------------------------------------------------------
--
Ilyas Yildirim
---------------------------------------------------------------