AMBER Archive (2007)Subject: Re: AMBER: Thermodynamic Integration with Explicit Solvent
From: Scott Pendley (scott.pendley_at_gmail.com) 
Date: Wed Oct 10 2007 - 17:38:20 CDT
 
 
 
 
David and Thomas
 
 I am trying this again following David's suggestions.  Using the follow
 
group and input scripts (no shake this time) with serial and parallel  (with
 
-ng  2) produced good results (see below)
 
 -O -i ../TI-exe-water/mdTI.in.01 -p Octane.ES-TI.parm -c
 
../Octane.ES.md1.rst -o Octane.ES-TI.step01.out . . .
 
-O -i ../TI-exe-water/mdTI.in.01 -p 2-Octanone-Dummy.ES-TI.parm -c
 
2-Octanone-Dummy.ES-TI.eq3.rst -o 2-Octanone-Dummy.ES-TI.step01.out . . .
 
  &cntrl
 
   ntr=0,
 
   nstlim=3000000, nscm=2000, ntave=5000,
 
   ntx=7, irest=1, ntb=1, ntpr=100,
 
   ntp=0, taup=2.0,
 
   dt=0.001, nrespa=2,
 
   ntt=0, temp0 = 300., tautp=2.0,
 
   ntc=1, ntf=1,
 
   ntwr = 10000, ntwx=0,
 
   cut=9.0,
 
 /
 
  NSTEP =      100   TIME(PS) =   13120.100  TEMP(K) =   238.47  PRESS =
 
0.0
 
 Etot   =    -12387.5794  EKtot   =      3425.4284  EPtot      =    -
 
15813.0077
 
 BOND   =      3406.0695  ANGLE   =         7.6728  DIHED      =
 
4.4646
 
 1-4 NB =         2.1128  1-4 EEL =        -0.0882  VDWAALS    =
 
2849.9746
 
 EELEC  =    -22083.2139  EHBOND  =         0.0000  RESTRAINT  =
 
0.0000
 
 Ewald error estimate:   0.1731E-03
 
 ------------------------------------------------------------------------------
 
 . . . .
 
 NSTEP =      400   TIME(PS) =   13120.400  TEMP(K) =   255.37  PRESS =
 
0.0
 
 Etot   =    -12374.7257  EKtot   =      3668.2543  EPtot      =    -
 
16042.9800
 
 BOND   =      1713.4225  ANGLE   =         8.0322  DIHED      =
 
3.4233
 
 1-4 NB =         2.4275  1-4 EEL =        -0.0886  VDWAALS    =
 
3165.7025
 
 EELEC  =    -20935.8993  EHBOND  =         0.0000  RESTRAINT  =
 
0.0000
 
 Ewald error estimate:   0.8989E-04
 
 ------------------------------------------------------------------------------
 
 We run into problems though when we added thermodynamic integration (icfe=1,
 
clambda = 0.00, klambda=6).  The job terminated abnormally about 400 steps.
 
The regular energy values seem normal however the DV/DL problems are huge
 
despite clambda = 0.00.
 
  NSTEP =      100   TIME(PS) =   13120.100  TEMP(K) =   238.47  PRESS =
 
0.0
 
 Etot   =    -12387.5794  EKtot   =      3425.4284  EPtot      =    -
 
15813.0077
 
 BOND   =      3406.0695  ANGLE   =         7.6728  DIHED      =
 
4.4646
 
 1-4 NB =         2.1128  1-4 EEL =        -0.0882  VDWAALS    =
 
2849.9746
 
 EELEC  =    -22083.2139  EHBOND  =         0.0000  RESTRAINT  =
 
0.0000
 
 DV/DL  = **************
 
 Ewald error estimate:   0.1731E-03
 
 ------------------------------------------------------------------------------
 
. . . .
 
NSTEP =      400   TIME(PS) =   13120.400  TEMP(K) =   255.37  PRESS =
 
0.0
 
 Etot   =    - 12374.7257  EKtot   =      3668.2543  EPtot      =    -
 
16042.9800
 
 BOND   =      1713.4225  ANGLE   =         8.0322  DIHED      =
 
3.4233
 
 1-4 NB =         2.4275  1-4 EEL =        -0.0886  VDWAALS    =
 
3165.7025
 
 EELEC  =    -20935.8993  EHBOND  =         0.0000  RESTRAINT  =
 
0.0000
 
 DV/DL  = **************
 
 Ewald error estimate:   0.8989E-04
 
 ------------------------------------------------------------------------------
 
 Any suggestions,
 
 Thank you,
 
 Scott
 
 -----------------------------------------------------------------------
 
The AMBER Mail Reflector
 
To post, send mail to amber_at_scripps.edu
 
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 
 
  
 |