AMBER Archive (2007)Subject: RE: AMBER: Help WARNING: The unperturbed charge of the unit
From: saccenti_at_cerm.unifi.it 
Date: Tue Sep 25 2007 - 07:23:25 CDT
 
 
 
 
Hi Steve,
 
 I indeed found out this solution: in CYM the net charge is -1
 
I can prepare a CU(I) prep file with charge +1 so that the total charge
 
is -1x3 + 1 = -2.
 
 I'm pretty new to this, but I have been warned that charges must be
 
distribuited over all the atoms of the complex:
 
                            (-1)CYG       CYG(-1)
 
                                  \Cu(+1)/
 
                                    |
 
                                   CYC(-1)
 
 I do not know if this is correct
 
 The parameters I was using comes from CYG-Cu-CYG and in that case the sum
 
over the Cu and CYG charges is indeed -1
 
 For the moment I'm using the same approach you kindly suggested but I'm
 
also looking for some reliable information about charge redistribution in
 
a such system with 3 cysteines and a copper(I)
 
 Any more details or suggestion is more than welcome
 
 Greets
 
Edo
 
 > Hi Edo,
 
>
 
> I don't know if this would be appropriate for your system, but at least
 
> it's
 
> worth checking out.
 
>
 
> Parameters for an anionic cysteine have already been determined according
 
> to
 
> the descriptions of most force fields and are actually already built into
 
> the residue libraries for most of the Amber force fields.  The residue
 
> name
 
> is CYM.  If you simply change the names of the residues in your PDB file
 
> from CYG to CYM, leap will read the built-in parameters and you don't even
 
> need the CYG prep file.
 
>
 
> Steve
 
>
 
>
 
> -----Original Message-----
 
> From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu] On Behalf
 
> Of
 
> Ilyas Yildirim
 
> Sent: Monday, September 24, 2007 5:54 PM
 
> To: amber_at_scripps.edu
 
> Subject: Re: AMBER: Help WARNING: The unperturbed charge of the unit
 
>
 
> Dear Edo,
 
>
 
> You have created a new CYG residue and new charge parameter for CU atom.
 
> The new CYG residue has a total charge of -0.698, and CU is 0.396. In
 
> your inpdb file, you have 3 CYG, and 1 CU, and when you add them up, the
 
> total charge of the system is -1.698000.
 
>
 
> Where did you get these parameters? Also, do you know what the total
 
> charge of your structure is? The new CYG residue - I guess - should
 
> have a -1 charge (The title of the CYG_prep is 'CYSTEINE with negative
 
> charge'). You might want to follow the resp procol to calculate the
 
> resp charges for your new CYG residue.
 
>
 
> I cant say too much about your system, or what to do with the 3 CYG - Cu
 
> region, but the reason why you see noninteger number is due to the charges
 
> defined for CYG and CU.
 
>
 
> Good luck,
 
>
 
> On Mon, 24 Sep 2007 saccenti_at_cerm.unifi.it wrote:
 
>
 
>> Dear All,
 
>> I'm getting the following
 
>>
 
>> Checking Unit.
 
>> WARNING: There is a bond of 3.363639 angstroms between:
 
>> -------  .R<CYG 87>.A<SG 8> and .R<CU 148>.A<CU 1>
 
>> ERROR: The unperturbed charge of the unit: -1.698000 is not integral.
 
>> WARNING: The unperturbed charge of the unit: -1.698000 is not zero.
 
>>
 
>>  -- ignoring the error and warnings.
 
>>
 
>> I'm aware that the total charge must be equal to zero
 
>> and also think that this must depend or on CGY or Cu or on both.
 
>>
 
>> I browsed the amber archive and tried several suggestion, but I'm still
 
>> getting that error
 
>>
 
>> Does somebody as some idea on how to fix this bug?
 
>> I attach the files I'm using
 
>>
 
>> Many thanks
 
>> edo
 
>>
 
>>
 
>
 
> --
 
>   Ilyas Yildirim
 
>   ---------------------------------------------------------------
 
>   = Department of Chemistry      -                              =
 
>   = University of Rochester      -                              =
 
>   = Rochester, NY 14627-0216     - Ph.:(585) 275 67 66 (Office) =
 
>   = http://www.pas.rochester.edu/~yildirim/                     =
 
>   ---------------------------------------------------------------
 
>
 
> -----------------------------------------------------------------------
 
> The AMBER Mail Reflector
 
> To post, send mail to amber_at_scripps.edu
 
> To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 
>
 
>
 
>
 
> -----------------------------------------------------------------------
 
> The AMBER Mail Reflector
 
> To post, send mail to amber_at_scripps.edu
 
> To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 
>
 
 
-- 
Dr Edoardo Saccenti
CERM Magnetic Resonance Center
University of Florence
Fiorgen Foundation
Via Luigi Sacconi n° 6
50019 Sesto Fiorentino
(FI) Italy
Tel: +39 055 4574281
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
  
  
 |