AMBER Archive (2007)Subject: Re: AMBER: Using ntr=1 in xleap
From: Carlos Simmerling (carlos.simmerling_at_gmail.com) 
Date: Fri Aug 31 2007 - 16:49:14 CDT
 
 
 
 
you need to set -ref <file> in the sander script.
 
<file> is the coordinates that you want as the reference for the restraints.
 
 On 8/31/07, Lili Peng <lilipeng_at_gmail.com> wrote:
 
>
 
> Hi all,
 
>
 
> I'm having problems running a two-fold minimization procedure on a
 
> 20-residue polyglutamic acid structure.  I'd like to 1) minimize the solvent
 
> (TIP3PBOX) while keeping the polypeptide fixed and 2) minimize the entire
 
> system.  However, in my initial minimization of solvent, I run into the
 
> error "Unit 10 Error on open: refc".  I'm pretty sure the error has to do
 
> with my setting ntr=1, because when i turn ntr off (=0), Sander executes the
 
> minimization smoothly.
 
>
 
> My input line for running Sander is:  "/sander.1cpu -O -i min_classical.in
 
> -o min_classical.out -p GLU20_alpha.prmtop GLU20_.inpcrd -r
 
> min_classical.rst"
 
>
 
> My minimization script is the following:
 
>
 
> "Initial minimization of solvent
 
>  &cntrl
 
>  imin=1, maxcyc=200, ncyc=50, ntpr=10,
 
>  cut=8.0, ntb=1, ntc=2,
 
>  ntr=1, restraintmask=':1-20',
 
>  restraint_wt=10.0
 
>  /
 
> "
 
>
 
> Does anyone know what could the problem?
 
>
 
> Thanks,
 
>
 
> Lili
 
>
 
>
 
>
 
>
 
>
 
 -----------------------------------------------------------------------
 
The AMBER Mail Reflector
 
To post, send mail to amber_at_scripps.edu
 
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 
 
  
 |