AMBER Archive (2007)Subject: Re: AMBER: Prepin error (?) in xleap
From: Junmei Wang (junmwang_at_yahoo.com)
I found your mol2 and pdb files do not contain hydrogen atoms. Antechamber only works for molecules without open valences.
Best
Junmei
Lili Peng <lilipeng_at_gmail.com> wrote: Hi Dr. Case,
Thanks for your reply. I tried running antechamber initially (as you prescribed), but my converted mol2 file is really weird. The carbon atoms get converted to Californium and Cerium atoms. There's even a Neon atom in the structure, as well as many "Unknowns". I have no idea how the carbon atoms got converted into them.
I have attached the original PDB and mol2 files for your convenience.
Thanks,
On 8/27/07, David A. Case < case_at_scripps.edu > wrote:On Fri, Aug 24, 2007, Lili Peng wrote:
> I created it using prepgen in antechamber:
There could be a problem with prepgen here, but my best guess is that you
If you want to make a GLU3 residue, you probably want to just use antechamber
antechamber -fi pdb -i glu3.pdb -fo mol2 -o glu3.mol2 -c bcc
If your GLU3 residue has a non-zero net charge, you will also need the "-nc"
This path ensures that you get gaff atom types. It looks like you are
...dac
-----------------------------------------------------------------------
| |||||||||||||||||||||||||||||||||
|