AMBER Archive (2007)

Subject: RE: AMBER: extracting starting structures from equilibration trajectory

From: Ilyas Yildirim (yildirim_at_pas.rochester.edu)
Date: Thu Jun 07 2007 - 14:58:19 CDT


Just ignore this email. Carlos Simmerling's solution (which is part of
amber) is better than this.

On Thu, 7 Jun 2007, Ilyas Yildirim wrote:

> You can write a script which will search the files in a directory once in
> a while (let's say once in 2 minutes), and save the .rst file. You
> will run this script while your sander job is running. Other than
> that, I dont think that sander has an option to save the .rst files the
> way u ask.
>
> On Thu, 7 Jun 2007, Nikola Trbovic wrote:
>
> > Thanks for the quick reply!
> >
> > Is there perhaps a way to save .rst files at regular intervals during the
> > equilibration run in a way that they are not overwritten?
> >
> > -----Original Message-----
> > From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu] On Behalf Of
> > Ilyas Yildirim
> > Sent: Thursday, June 07, 2007 2:14 PM
> > To: amber_at_scripps.edu
> > Subject: Re: AMBER: extracting starting structures from equilibration
> > trajectory
> >
> > The .mdcrd files do not store any velocity information. So, when u extract
> > the restart files from a .mdcrd file using ptraj, they wont have any
> > velocity information in them. As a result, u need to re-equilibrate each
> > system. Only .rst files have velocity info. in them.
> >
> > On Thu, 7 Jun 2007, Nikola Trbovic wrote:
> >
> > > Dear all,
> > >
> > >
> > >
> > > I'm trying to use snapshots from an NPT equilibration trajectory as
> > starting
> > > structures for several NVE production runs. I tried extracting snapshots
> > as
> > > Amber restart files from the equilibration trajectory as follows:
> > >
> > >
> > >
> > > ptraj prmtop << EOF
> > >
> > > trajin equi.mdcrd 300 1000 100
> > >
> > > trajout start restart
> > >
> > > EOF
> > >
> > >
> > >
> > > This produces 8 restart files from the equilibration trajectory, just like
> > I
> > > want it to. But when I start the production runs with irest=1 and ntx=5,
> > the
> > > temperature starts out around 190K, although it is clearly equilibrated at
> > > 300K in the time window of the NPT equilibration trajectory that I
> > specified
> > > for extracting the starting structures by ptraj. How do I fix this?
> > >
> > >
> > >
> > > Thanks a lot in advance for any suggestions,
> > >
> > > Nikola
> > >
> > >
> >
> >
>
>

-- 
  Ilyas Yildirim
  ---------------------------------------------------------------
  - Department of Chemistry      -				-
  - University of Rochester      -				-
  - Hutchison Hall, # B10        -				-
  - Rochester, NY 14627-0216     - Ph.:(585) 275 67 66 (Office)	-
  - http://www.pas.rochester.edu/~yildirim/			-
  ---------------------------------------------------------------

----------------------------------------------------------------------- The AMBER Mail Reflector To post, send mail to amber_at_scripps.edu To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu