AMBER Archive (2007)Subject: Re: AMBER: nscm in simulation annealing
From: David A. Case (case_at_scripps.edu) 
Date: Thu Apr 12 2007 - 19:05:01 CDT
 
 
 
 
On Thu, Apr 12, 2007, Hu, Shaowen (JSC-SK)[USRA] wrote:
 
 > Thank you very much, Dr. Case. I am using AMBER 9. However, I can not
 
> find the restriction. With ntt=3, if I did not set nscm=0, the default
 
> value is 1000. 
 
 Yes, but nscm only repositions the center of mass; it does not modify the
 
velocities.  We would need more information about why or how you think the
 
temperature behavior is odd.  Be sure to state what value of gamma_ln you are
 
using, how big the system is, and how you monitored behavior.
 
 ....dac
 
 -----------------------------------------------------------------------
 
The AMBER Mail Reflector
 
To post, send mail to amber_at_scripps.edu
 