AMBER Archive (2007)Subject: AMBER: temperature artifacts with andersen and GB?
From: David Mobley (dmobley_at_gmail.com) 
Date: Wed Apr 11 2007 - 11:50:17 CDT
 
 
 
 
All,
 
 I know the manual highly recommends using Langevin for temperature
 
control when using GB, but I insisted on trying Andersen anyway while
 
simulating a small molecule. I find that the average temperature (in
 
vacuum, or in GB solvent) is consistently too low (i.e., average of
 
250K over 500000 steps, when thermostatting to 300K, with vrand=500).
 
Looking at the instantaneous temperatures from the energy file, which
 
I'm writing every hundred steps, I find that immediately after every
 
randomization, the "temperature" spikes to about 2800K, then wobbles
 
around somewhere in teh 100-250K range until the next randomization.
 
 I'm now going to Langevin, which seems to be working fine. But I don't
 
see any reason why  the Andersen thermostat should give this behavior,
 
so it might be worth looking into.
 
 Thanks,
 
David
 
-----------------------------------------------------------------------
 
The AMBER Mail Reflector
 