AMBER Archive (2007)Subject: RE: AMBER: AM1-bcc
From: Junmei Wang (jwang_at_encysive.com)
Date: Tue Feb 27 2007 - 20:57:23 CST
Antechamber first performs AM1 optimization to get Mulliken charges and
then does bond charge correction.
All the best
Junmei
From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu] On Behalf
Of Evan Kelly
Sent: Tuesday, February 27, 2007 6:26 PM
To: amber_at_scripps.edu
Subject: AMBER: AM1-bcc
Can someone verify that the AM1 atomic charges (to which the
bond charge corrections are applied) used in Antechamber's AM1-bcc
charge fitting algorithm are in fact Mulliken charges from an AM1
calculation? If so, does Antechamber perform a single point calculation
on the inputted molecule, or does it do any energy minimization?
Thanks!
----------------------------------
Evan Kelly
ebkelly_at_ualberta.ca
-----------------------------------------------------------------------