AMBER Archive (2007)Subject: RE: AMBER: Why there is a gap or jump if continue ntt=3 or ntt=1
From: Jiapu.Zhang_at_csiro.au
Dear Ross,
Thank you very much for your helps.
Yes, I set irest=1 and ntx=7 in both input files, see:
md1_heat_A.in (start from the *.rst gotten at 300K):
Stage 1: 300K-400K and 400K-400K
&cntrl
imin = 0,
irest = 1,
ntx = 7,
ntb = 1,
cut = 12,
ntr = 1,
ntc = 2,
ntf = 2,
tempi = 300.0,
temp0 = 400.0,
ntt = 3,
gamma_ln = 1.0,
nstlim = 900000, dt = 0.0005,
ntpr = 100, ntwx = 100, ntwr = 1000,
nmropt = 1
/
&wt type='TEMP0', istep1=0, istep2=400000,
value1=300.0, value2=400.0
/
&wt type='TEMP0', istep1=400001, istep2=900000,
value1=400.0, value2=400.0
/
&wt type='END'
/
Keep the protein restrained with weak restraints
10.0
RES 1 104
END
END
md1_heat_A_continuation.in:
Stage 1: 400K-400K
&cntrl
imin = 0,
irest = 1,
ntx = 7,
ntb = 1,
cut = 12,
ntr = 1,
ntc = 2,
ntf = 2,
temp0 = 400.0,
ntt = 3,
gamma_ln = 1.0,
nstlim = 900000, dt = 0.0005,
ntpr = 100, ntwx = 100, ntwr = 1000,
nmropt = 1
/
&wt type='TEMP0', istep1=0, istep2=900000,
value1=400.0, value2=400.0
/
&wt type='END'
/
Keep the protein restrained with weak restraints
10.0
RES 1 104
END
END
In the second input file, I change ntt=3 into ntt=1 (with tautp=2.0),
By the way, could you please teach me how to choose the value of the
Great thanks to you for your help.
Best regards,
Jiapu
-----Original Message-----
Dear Jiapu,
Can you post the input files for phase I and II? Are you definately
All the best
Ross
/\
| HPC Consultant and Staff Scientist |
Note: Electronic Mail is not secure, has no guarantee of delivery, may
From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu]
Dear Amber friends,
Recently when I do equilibration, first the system was warmed up
Sincerely yours,
Jiapu
-----------------------------------------------------------------------
| |||||||||||||||||||||||||||||||||
|