AMBER Archive (2007)

Subject: RE: AMBER: Deep energetics problem

From: Ross Walker (ross_at_rosswalker.co.uk)
Date: Tue Jan 02 2007 - 13:12:53 CST


Dear Vikram,
 
This could be from a number of issues although the most likely is the
restraint force. 1000 KCal/mol/A2 is far too strong. What this will do is
induce very high frequency oscillations in the CA atom which are too fast
for the 2 fs step of your integrator and hence the system blows up. Do you
really need to keep CA of residue 1 fixed this tightly? Try something
smaller like 50.0 or so. Even this is large but it should work.
 
You might also have issues with your system not being minimised /
equilibrated properly. How well equilibrated were things from the run from
which you are restarting this?
 
I would start by just reducing the restraint force and see how you do. Note,
you may want to set nstlim to say 1000 and ntwx/ntpr=1 so that you get a
short run with every frame recorded. Then you can watch what happens to the
system. You may also want to reduce the timestep to say 1fs or so to ensure
better stability.
 
All the best
Ross

/\
\/
|\oss Walker

| HPC Consultant and Staff Scientist |
| San Diego Supercomputer Center |
| Tel: +1 858 822 0854 | EMail:- ross_at_rosswalker.co.uk |
| http://www.rosswalker.co.uk <http://www.rosswalker.co.uk/> | PGP Key
available on request |

Note: Electronic Mail is not secure, has no guarantee of delivery, may not
be read every day, and should not be used for urgent or sensitive issues.

 

  _____

From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu] On Behalf Of
sai vikram
Sent: Tuesday, January 02, 2007 09:10
To: amber_at_scripps.edu
Subject: AMBER: Deep energetics problem

Hi,

I am trying to do a NPT simulation with a protein structure restraining

Restrain 2 to 20 residues

1.0

Restrain the CA atom of first residue strongly

1.0

Before this particular run i carried out a minimization amd Simulated
annealing step with restrains.
 
  50.0
 RES 2 20
 Restrain the CA atom of first residue strongly
 1000.0
 

I wish my system should be at constant pressure 200.0 .

****************************************************************************
***

Error:

vlimit exceeded for step 6; vmax = 59.1247

     Coordinate resetting (SHAKE) cannot be accomplished,
     deviation is too large
     NITER, NIT, LL, I and J are : 0 2 78 140 141

     Note: This is usually a symptom of some deeper
     problem with the energetics of the system.

****************************************************************************
***

I have tried to search in google and read the messages posted previously
by others, and reduced the restraints as per their suggestions. Yet, i could
not able to run my system

$ Can someone please advice me here. below is my input file
 
Input file is
----------------------------------------------------------------------------
----------------------------------------
 &cntrl
  imin = 0, ntx = 7, irest = 1,
  ntpr = 100, ntwx = 500, ntwe = 0, ntwprt=0,
  ntc = 2, ntf = 2,
  nstlim = 50000, dt =0.002,
  tempi=300.0, temp0 = 300.0, ntt =1, tautp =2.0,
  ntb = 2, ntp = 1,taup=0.2, pres0=200.0,
  ntr=1,iwrap=1,cut=10.0
 &end
 Restrain the heavy atoms
 1.0
 RES 2 20
END
 Restrain the CA atom of first residue strongly
 1.0
 FIND
 * CA * *
 SEARCH
 RES 1
END
END
 

 
Amber Version : 9

 
Operating System : Linux

----------------------------------------------------------------------------
----------------------------------

Thanks in advance,

-Vikram

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu