AMBER Archive (2006)Subject: Re: AMBER: Simulating proteins with calcium ion
From: Bill Ross (ross_at_cgl.ucsf.edu)
Date: Fri Dec 22 2006 - 13:51:07 CST
Sigma and R* are different mathematically - I believe sigma is
where the potential curve crosses the zero point and R* is where
it is at a minimum. Also Aqvist values are derived for different
combining rules than amber uses, so they need to be adapted.
Discussion here:
http://amber.scripps.edu/Questions/vdw.html
Bill
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
|