AMBER Archive (2006)Subject: AMBER: SHAKE problem after minimization
From: Rachel (comeonsos_at_googlemail.com)
Dear all,
I have a problme with SHAKE after minimization, when I started to run md,
------------------------------------------------------------------------------------------------------------------
Coordinate resetting (SHAKE) was not accomplished
Note: This is usually a symptom of some deeper
And the following are the scripts i used to run minimization and md:
--------------------------------------------------------------------------------------------------------------
initial minimisation whole system
-------------------------------------------------------------------------------------------------------------
res on the protein with 0.5fs timestep
---------------------------------------------------------------------------------------------------------------------
I have tried to use even smaller timestep such as 0.3fs or even 0.1fs, but
Can anyone suggest what might be the causes of this SHAKE failure please?
Best regards,