AMBER Archive (2006)Subject: RE: AMBER: some puzzles in equilibration MD
From: Ross Walker (ross_at_rosswalker.co.uk)
Date: Mon Oct 09 2006 - 09:53:20 CDT
Dear Zhihong
> gamma_ln = 5.0, (REMARKS: if I use 1.0 only, the RMS of
> temperature is 68.96K, AVERAGE is 369.46K, the largest value
> is 478.01K, so I use 5.0, the result got better, RMS
> decreased to 26.16K, AVERAGE is 319.46, the largest value is
> 396.96K. In fact, I think the temperature contorl is not very
> satisfactory, what should I do? just keep increasing gamma_ln
> to 10.0 or do something else?)
This suggests that you may have a highly strained starting structure which
is giving you problems during the trajectory. The forces are probably very
high in one region and the thermostat can't cope with this.
> dt = 0.001, (REMARKS: I used dt = 0.002 at the beginning,
> but when the MD went to 398 step, error of "vlimit exceeded
> for step 398; vmax = 128.7932, Coordinate resetting cannot be
> accomplished, deviation is too large" took place, so I
> decreased it to dt = 0.001, and restrained the solute only by
> 2.0 force constant, then the MD could complete. But, when I
> checked the md out file, I found many many "vlimit exceeded
> for step" warnings have appeared from beginnig to ending, so
> I wondered whether this equilibration MD is valid?
This confirms it you have major issues with your initial structure. The fact
that you need a 1fs time step even with shake on implies that you have some
highly strained atoms somewhere. Try minimising the system and on step 1 see
which atom has the highest force. Are any energy values too high? E.g. VDW,
EEL or bond? Visualize the system and take a look at the region around atom
reported to have the highest force. Is anything wrong here?
You could also try setting ntpr=1 and ntwx=1 with nstlim=200 and re-running
your MD. This will write data to the trajectory file on every step of MD.
You can then load this into something like VMD and visualise the movement on
every time step. If there are structural problems it should be easy to see.
> Can I
> perform the second NTP equilibration MD based on this MD results? )
I wouldn't. I would fix the problems with the starting structure first.
All the best
Ross
/\
\/
|\oss Walker
| HPC Consultant and Staff Scientist |
| San Diego Supercomputer Center |
| Tel: +1 858 822 0854 | EMail:- ross_at_rosswalker.co.uk |
| http://www.rosswalker.co.uk | PGP Key available on request |
Note: Electronic Mail is not secure, has no guarantee of delivery, may not
be read every day, and should not be used for urgent or sensitive issues.
-----------------------------------------------------------------------
The AMBER Mail Reflector