AMBER Archive (2006)Subject: RE: AMBER: Amber8: problem related to antechamber
From: Junmei Wang (jwang_at_encysive.com)
Date: Tue Sep 26 2006 - 16:15:07 CDT
Besides Dave's comment, please bear in mind that the following message
is just for information, not a real error:
"The atom number exceeds the MAXATOM, reallocate memory"
Junmei
On Fri, Sep 22, 2006, priya priya wrote:
>
> I have a peptoid sequence (in peptoids the amino acid
> side chain is attached to the nitrogen instaed of
> carbon wrt proteins) of about 12-15 residues.
>
> I cannot load this molecule in antechamber.It says
> "The atom number exceeds the MAXATOM, reallocate
> memory".
Antechamber is designed to work with single residues at a time. You
should use it to create a unit for each peptoid residue you have, then
use LEaP to link them together into a polymer in the same way you would
for a regular protein.
...good luck...dac
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
|