AMBER Archive (2006)Subject: AMBER: Etot has downward drift in 'NVE' ensemble
From: John S. Zintsmaster (jzintsma_at_nd.edu)
Date: Wed Jul 12 2006 - 21:01:08 CDT
Hello All,
I am attempting to run a microcanonical ensemble of about 6000 atoms. Here is my
input file:
&cntrl
nstlim=500000, dt=0.001, ntx=5, irest=1,
ntpr=500, ntwr=500, ntwx=500, ntwv=500,ntwe=100
tempi=300.0, ntt=0, tautp=2.0,
ntb=1, ntp=0,
ntc=2, ntf=2,
nrespa=1,
&end
I am experiencing a DOWN-ward drift in my total energy. I know that with a
similarly equilibrated system, with the same input file except for dt=0.002 I
experience the "normal" less than optimal upward drift in Etot. Has anyone had
anything like this downward drift happen to them or know of the right paramter
to tweek until a more true NVE ensemble is held. Thanks in advance.
Johnny
--
John S. Zintsmaster
251 Nieuwland Science Hall
Dept of Chemistry and Biochemistry
University of Notre Dame
Notre Dame, IN 46556
phone: 574-631-0285
fax: 574-631-6652
e-mail: jzintsma_at_nd.edu
website: www.nd.edu/~jzintsma
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
|