AMBER Archive (2004)

Subject: Re: AMBER: Implicit 4r md

From: David A. Case (case_at_scripps.edu)
Date: Fri Dec 03 2004 - 10:48:00 CST


On Thu, Dec 02, 2004, yen li wrote:

> But the total energies are still comming positive. Can
> somebody help me in finding the exact problem.

The absolute energy for a force field calculation is rarely meaningful. You
haven't said anything about the breakdown of the energies into pieces, but
it could be that the 1-4 electrostatics is positive for all reasonable
configurations. Only energy differences between conformations should be
meaningful.

This doesn't mean there is no problem, but there may not be.

...dac

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu