> somebody help me in finding the exact problem.
The absolute energy for a force field calculation is rarely meaningful. You
haven't said anything about the breakdown of the energies into pieces, but
it could be that the 1-4 electrostatics is positive for all reasonable
configurations. Only energy differences between conformations should be
meaningful.
This doesn't mean there is no problem, but there may not be.