AMBER Archive (2004)Subject: Re: AMBER: GB and langevin dynamics
From: David A. Case (case_at_scripps.edu) 
Date: Mon Sep 13 2004 - 14:59:31 CDT
 
 
 
 
On Thu, Sep 09, 2004, Sergio E. Wong wrote:
 
> 
 
> 
 
>     I'm concerned b/c I ran a GB + langevin dynamics simulation of a short
 
> peptide (ACE GLY SER SER SER NME) and the average temperature (over
 
> 500,000 steps = 0.5 ns) is about 10 degrees above the target temperature.
 
 I haven't seen this in simulations we have done.  You might check that
 
energy is conserved wtih temperature coupling turned off (ntt=0) for your
 
system.  Also worth checking is the value of nscm you use (try a value of
 
1000 or 2000), to see if that makes a difference.  You could also try
 
increasing gamma_ln, but this shouldn't make a difference, and doesn't in
 
my test cases.
 
 In the end, we may have to get your input files to see what is really
 
happening...you are correct to be concerned about this sort of result.
 
 ...good luck...dac
 
 -----------------------------------------------------------------------
 
The AMBER Mail Reflector
 
To post, send mail to amber_at_scripps.edu
 
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu
 
 
  
 |