AMBER Archive (2004)

Subject: RE: AMBER: amber8 tutorial

From: Ross Walker (ross_at_rosswalker.co.uk)
Date: Sun Apr 04 2004 - 21:45:52 CDT


Dear Sachin,
 
The polyA-polyT tutorial has been updated and is now designed to work with
AMBER 8 which uses TIP3PBOX for a box of TIP3P water. Previous versions of
amber used WATBOX216 for this.
 
Thus the command:
 
solvatebox model WATBOX216 8.0
 
should work.
 
I'll add a note about this to the tutorial tomorrow.
 
All the best
Ross
 
/\
\/
|\oss Walker

| Department of Molecular Biology TPC15 |
| The Scripps Research Institute |
| Tel:- +1 858 784 8889 |
| EMail:- ross_at_rosswalker.co.uk |
| http://www.rosswalker.co.uk/ | PGP Key available on request |

  _____

From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu] On Behalf Of
Patil, Sachin
Sent: 04 April 2004 17:03
To: amber_at_scripps.edu
Subject: AMBER: amber8 tutorial

Hi,
I am running polyA-polyTtutorial for amber8 on my
redhat9 machines which has amber7 installed on it.

Everything went fine untill I used following is xleap

>solvatebox model TIP3PBOX 8.0

I got the following error message

solvateBox : Aurgument #2 is type string must be of type : [unit]
usage :solvateBox <solute> <solvent> <buffter> [iso] [closeness]

I dont know what this error message means. But it doesnot solvate the DNA.
And it doesnot save the polyAT_wat.prmtop and polyAT_wat.inpcrd files, since
they remain empty.

** one interesting point is that, i dont have TIP3 files in the
/amber7/dat/solvents folder.

If anybody has any idea please help !

thanks in advance.

regards
sachin

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber_at_scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu