AMBER Archive (2004)

Subject: Re: AMBER: Temperature in Nmode

From: David A. Case (case_at_scripps.edu)
Date: Tue Feb 10 2004 - 10:42:06 CST


On Tue, Feb 10, 2004, ML wrote:

> I found that default temperature for nmode is 298.15. How do I change
> this to 300K?
>

You can set the variable "t" in the &data input to the temperature you
want. (Somehow, this never made it into the manual.)

...regards...dac
-----------------------------------------------------------------------