Subject: Re: AMBER: Vlimit problem

From: David A. Case (case_at_scripps.edu)
Date: Thu Jan 08 2004 - 18:31:00 CST


You wrote:

> I have encountered a problem with vlimit when runing the simulation of an
> unmodified control of a 11mer B - DNA with 20 Na+ counterions added and
> waterbox of 10 A in each dimension. I set vlimit=15.0 for the second step
> "dynamics holding the solute fixed",after 1000 steps of steepest descent
> minimization and 4000 steps of conjugate gradient minimization.

You have to heat the system to the final temperature (say 300K) at constant
volume *before* you turn on constant pressure.

Also, please send email to the list as plain text, not as html.

..good luck..dac

-- 

================================================================== David A. Case | e-mail: case_at_scripps.edu Dept. of Molecular Biology, TPC15 | fax: +1-858-784-8896 The Scripps Research Institute | phone: +1-858-784-9768 10550 N. Torrey Pines Rd. | home page: La Jolla CA 92037 USA | http://www.scripps.edu/case ================================================================== ----------------------------------------------------------------------- The AMBER Mail Reflector To post, send mail to amber_at_scripps.edu To unsubscribe, send "unsubscribe amber" to majordomo_at_scripps.edu