AMBER Archive (2003)Subject: RE: AMBER: Not getting restrt file on running sanders
From: Asim Okur (aokur_at_ic.sunysb.edu)
Date: Thu Oct 09 2003 - 16:53:37 CDT
To be able to write a restrt file you have to use ntwr in the input
file.
ntwr = 10
will write to the restart file every 10 steps,
Asim Okur
-----Original Message-----
From: owner-amber_at_scripps.edu [mailto:owner-amber_at_scripps.edu] On Behalf
Of Vikas Varshney
Sent: Thursday, October 09, 2003 5:40 PM
To: amber_at_scripps.edu
Subject: AMBER: Not getting restrt file on running sanders
Dear AMBER users,
I tried to run minimization of a system of around 500 residues (~5000
atoms) in
sander with option -r restart, but did not get the restart file. Here is
my input file.
Minimization
&cntrl
imin=1,maxcyc=100000,ntmin=2,
ntpr=10,iwrap=1,
&end
Group input for restrained atoms
2.0
RES 383 478
END
END
I will really appreciate if you are can help me with this.
Many regards and thanks,
VIkas Varshney
Dept. of polymer science
University of Akron.