| AMBER Archive (2003)Subject: Re: translational and rotational motion (more information)
From: Carlos Simmerling (carlos_at_csb.sunysb.edu)Date: Thu May 22 2003 - 08:35:13 CDT
 
 
 
 
This is a problem with vacuum simulations
in AMBER6. You should upgrade to AMBER7,
 it has fixed this problem and has many other advantages.
 I do not think that there is a simple bugfix for
 this, but someone can correct me if I am wrong.
 I can show you how to modify the code to fix
 this but upgrading to AMBER7 is probably a
 better choice.
 Carlos
 
 ----- Original Message -----
From: "Jean-François Taly" <jftaly_at_jouy.inra.fr>
 To: <amber_at_heimdal.compchem.ucsf.edu>; <carlos.simmerling_at_stonybrook.edu>
 Sent: Thursday, May 22, 2003 9:25 AM
 Subject: translational and rotational motion (more information)
 
 >
>
 > hi! I am doing some vacuum simulations with sander with constant
 > temperature.
 >
 > I'm using AMBER6, whith no periodic condition.
 >
 > My problem is I see my protein moving whith a rotational motion.
 >
 > I found in the mail reflector some explaination about the ntcm or nscm
 flag:
 >
 > "The only time you
 > should see significant numbers in the above message is after initial
 > random velocity assignment (which will likely lead to a small
 > translational componenet) of if energy is poorly conserved (due to
 > infrequent pairlist update, no buffered/skin pairlist, SHAKE tolerances
 > that are too low, time steps that are too large, ...)."
 >
 > Indeed, I start my simulation with random velocity from the maxwell
 > distribution.
 > But the Non bonded pair list is updated every 10 steps (I assume it is
 > quite frequent)
 > So I stop using shake and I put my time step to 1 fentosecond
 > (previously 2 fento)
 >
 > But even when I use nscm =1000, for the first printing step I see that
 > something happened :
 >
 > "check COM velocity, temp:        0.011485     0.16(Removed)"
 >
 > Next I never see something else that
 >
 > "check COM velocity, temp:        0.000000     0.00(Removed)"
 >
 > But when I watch my trajectory with VMD, I see the rotational motion.
 >
 > And I see the potential energy droping down progrisively, kinetic energy
 > is  stable; so the total is droping down too.
 >
 > I have several question :
 >
 > Could you explain me why there is a lost of energy and is there anyway
 > to avoid that kind of motion?
 >
 > Is it a problem for carnal or ptraj to do the RMSd calculation?
 >
 > thanks
 >
 > jean-françois TALY
 >
 >
 > here my input file :
 >
 >   &cntrl
 >
 > ntx = 1, irest = 0, ntrx = 1, ntxo = 1,
 >
 > ntpr = 1000, ntwx = 1000, ntwr = 5000, ntwe = 1000,
 >
 >
 >
 > ntf = 1, ntb = 0, igb = 3,
 >
 > nsnb = 10, cut = 11.0,
 >
 >
 >
 > ibelly = 0, ntr = 0,
 >
 >
 >
 > imin = 0, nstlim = 250000,
 >
 > dt = 0.001,nscm = 1000, ndfmin = 6,
 >
 > ig     = 71277,ntt    = 1, tautp = 1.0,
 >
 >
 >
 > tempi = 10.0, temp0 = 300.0,
 >
 >
 >
 > vlimit = 20.0,
 >
 >
 >
 > ntc = 1, tol = 0.0005,
 >
 >   &end
 >
 >
 >
 
 
 
 |