Hi,
    You have a missing angle parameter for S-CU-S. You need to define it
    first in your frcmod file for unit HIC.

On Tue, 15 Apr 2003, chandran karunakaran wrote:

> Could not find angle parameter: S - CU - S

-- 
Guanglei Cui