AMBER Archive (2003)

Subject: Re: minimization with fixed UC dimensions

From: David A. Case (case_at_scripps.edu)
Date: Fri Feb 21 2003 - 14:00:09 CST


On Fri, Feb 21, 2003, Ioana Cozmuta wrote:
>
> Is there an option in amber to perform minimization keeping the UC
> dimensions fixed and then release the angles and the lengths of the UC and
> minimize again?

There is no such option. It is not clear to me why one would want to do this.
Minimization (at best) corresponds to a zero Kelvin model (but without any
zero-point vibrations). You *can* optimize unit cell lengths (but currently
not the angles) at finite temperatures by carrying out constant pressure MD
simulations.

..hope this helps...dac

-- 

================================================================== David A. Case | e-mail: case_at_scripps.edu Dept. of Molecular Biology, TPC15 | fax: +1-858-784-8896 The Scripps Research Institute | phone: +1-858-784-9768 10550 N. Torrey Pines Rd. | home page: La Jolla CA 92037 USA | http://www.scripps.edu/case ==================================================================