AMBER Archive (2002)Subject: Re: Equilibration output Amber7
From: Guanglei Cui (cuigl_at_morita.chem.sunysb.edu) 
Date: Fri Nov 22 2002 - 08:42:02 CST
 
 
 
 
Hi, 
 
    COM stands for center of mass. Because you specified nscm = 1, which
 
means removing translation and rotation of COM is turned on, you had all
 
the COM messages. But I noticed that your EWALD error is quite big.
 
 On Fri, 2002-11-22 at 04:42, Fredrick Robin Devadoss wrote:
 
> Dear amber users,
 
> while running an equilibration, i got the following in the output 
 
> file........... check COM velocity, temp:    0.000002   0.00(Removed)
 
> it comes in between every 50 steps.......... like this.........
 
> 
 
> HERE IS THE OUTPUT:
 
> 
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> 
 
>  NSTEP =     50 TIME(PS) =     0.050  TEMP(K) =     6.33  PRESS =  
 
> 1764.8
 
>  Etot   =    4513.9746  EKtot   =     168.5182  EPtot      =    
 
> 4345.4564
 
>  BOND   =      14.0843  ANGLE   =     103.8661  DIHED      =     
 
> 387.9850
 
>  1-4 NB =     176.4341  1-4 EEL =     -10.8820  VDWAALS    =   
 
> -3307.9063
 
>  EELEC  =    6978.7228  EHBOND  =       0.0000  RESTRAINT  =       
 
> 3.1523
 
>  EAMBER (non-restraint)  =    4342.3042
 
>  EKCMT  =     123.2608  VIRIAL  =   -6858.4457  VOLUME     =  
 
> 183229.3353
 
>                                                 Density    =       
 
> 0.7435
 
>  Ewald error estimate:   0.5609E+00
 
>  
 
> ------------------------------------------------------------------------------
 
> 
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)           
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> check COM velocity, temp:        0.000002     0.00(Removed)
 
> 
 
> Like this, it's keep on going upto NSTEP=1000...........
 
> 
 
> Can anyone explain me why it is coming like this?
 
> my input file is as follows............
 
> 
 
> 
 
> Equilibration run for heating the system
 
>  &cntrl
 
>    imin = 0, ntx = 1, ntrx = 1, ntxo = 1, ntpr = 50,
 
>    irest = 0, ntwr = 1000, ntwx = 1000,
 
>    ntwv = 1000, ntwe = 1000, ntf = 2, ntc = 2,
 
>    cut = 8.0, igb = 0, scee = 1.2, scnb = 2.0,
 
>    nsnb = 25, dielc = 78.5, ntr = 1,
 
>    nstlim = 1000, nscm = 1, t = 0, dt = 0.001,
 
>    temp0 = 20.0, tempi = 0.0,
 
>    heat = 0.0, ntb = 2, ntt = 1, tautp = 0.10,
 
>    ntp = 1, pres0 = 1.0, comp = 44.6, taup = 0.2,
 
>    tol = 0.0001,
 
>  &end
 
>  &ewald
 
>    nfft1 = 64, nfft2 = 64, nfft3 = 64, order = 4,
 
>    ew_type = 0, dsum_tol = 0.00001, nbflag = 0,
 
>    eedmeth = 5,
 
>  &end
 
> group no 1
 
> 10
 
> RES 1 24
 
> END
 
> END
 
> 
 
> Can anyone explain me why it is coming like this?
 
> 
 
> thanks in advance
 
> 
 
> regards
 
> fredrick.
 
 
-- 
Guanglei Cui <cuigl_at_morita.chem.sunysb.edu>
SUNY at Stony Brook
 
  
 |