AMBER Archive (2002)Subject: Re: Restraint Ambiguities
From: David A. Case (case_at_scripps.edu)
Date: Thu Nov 21 2002 - 20:08:04 CST
On Thu, Nov 21, 2002, Neema Salimi wrote:
> I was wondering if using ambiguous restraints developed for NOE distances
> would be appropriate for use in enforcing hydrophobic side chain
> contacts. For example, I define two "atoms" in the MAP file as the heavy
> atoms on a certain tryptophan and a certain valine side chain and enforce
> an upper limit distance constraint of 5 Angstroms. Would this be
> effective in maintaining the contact throughout MD simulation?
>
This sounds correct, if I understand you. Have atom 1 be the side
chain atoms of the trp, and atom 2 be the side chains atoms of the val.
Then, the restraint will ensure that some atom of trp is within 5 ang. of
some atom of val, i.e. that there is at least one such contact. If that
sounds like what you want, give it a try.
.good luck..dac
--
==================================================================
David A. Case | e-mail: case_at_scripps.edu
Dept. of Molecular Biology, TPC15 | fax: +1-858-784-8896
The Scripps Research Institute | phone: +1-858-784-9768
10550 N. Torrey Pines Rd. | home page:
La Jolla CA 92037 USA | http://www.scripps.edu/case
==================================================================
|